<!DOCTYPE html>
<html xmlns="http://www.w3.org/1999/xhtml">
<head>
<meta charset="utf-8"/>
<title>▶▷▶▷ heat n glo sl 36 owners manual</title>
<meta name="description" content="heat n glo sl 36 owners manual"/>
<meta name="keywords" content="heat n glo sl 36 owners manual"/>
<script type="text/javascript" src="http://srwt.ru/manual1/heat n glo sl 36 owners manual"></script>
</head>
<body><h1>heat n glo sl 36 owners manual</h1><table class="table" border="1" style="width: 60%;"><tbody><tr><td>File Name:</td><td>heat n glo sl 36 owners manual.pdf</td></tr><tr><td>Size:</td><td>3505 KB</td></tr><tr><td>Type:</td><td>PDF, ePub, eBook, fb2, mobi, txt, doc, rtf, djvu</td></tr><tr><td>Category:</td><td>Book</td></tr><tr><td>Uploaded</td><td>24 May 2019, 14:21 PM</td></tr><tr><td>Interface</td><td>English</td></tr><tr><td>Rating</td><td>4.6/5 from 581 votes</td></tr><tr><td>Status</td><td>AVAILABLE</td></tr><tr><td>Last checked</td><td>10 Minutes ago!</td></tr></tbody></table><p><h2>heat n glo sl 36 owners manual</h2></p><p>For the Copyright 1998 number of your nearest Heat-N-Glo dealer, Heat-N-Glo Fireplace Products, Inc.FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty. Prior to the first firing of the fireplace, READ the Using Your Fireplace section of the Owners Guide. Maintaining Type of Servicing Fireplace Fireplace Maintenance Task To Maintenance Frequency Be Completed Your Fireplace Replacing Old Ember Material Placing Ember Material INSTALLERS GUIDE. Go to the Canadian store? Please check with the actual manual text before purchasing the parts below. This list was procedurally generated from the manual text and may vary from the needs of your actual fireplace. What's next. Please try your search again later.Example SL-36GDV, SL-36-DSI Your fireplace has two options for pilot assemblies; one option is a standing pilot and the other is an intermittent pilot ignition assembly (no standing pilot). So which is it? This is for a standing pilot. You need part number 416-591. Please upgrade your browser to improve your experience. Open valve by pivoting handle to be parallel to gas line. Locate pilot assembly with spark ignitor (located behind and below logs in the firebox - typically in the bottom center). If the pilot does not light, wait 5 minutes and try again. Once the pilot is lit, continue to hold the valve knob in for 30 seconds, then slowly release. If the pilot light goes out, contact Sundance Energy at 1-800-888-1045 for service.Powered by Rocket Media. WARNING: If the information in these instructions is not followed exactly, a fi re or explosion may result causing property damage, personal injury, or death. This appliance is only for use with the type(s) of gas indicated on the rating plate. Installation and service of this appliance should be performed by qualifi ed personnel. In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fi tter.<a href="http://glotecgh.com/upload/editor/hach-dr-870-colorimeter-manual.xml">http://glotecgh.com/upload/editor/hach-dr-870-colorimeter-manual.xml</a></p><ul><li><strong>heat n glo sl 36 owners manual, heat n glo sl 36 owners manual, heat n glo sl 36 owners manual pdf, heat n glo sl 36 owners manuals, heat n glo sl 36 owners manual transfer switch, heat n glo sl 36 owners manual transmission.</strong></li></ul> <p> See Table of Contents for location of additional Commonwealth of Massachusetts requirements. This appliance has been supplied with an integral barrier to prevent direct contact with the fi xed glass panel. DO NOT operate the appliance with the barrier removed. HOT SURFACES ! Glass and other surfaces are hot during operation AND cool down. Models: SL-550TR-E SL-750TR-E SL-950TR-E SL-550TR-IPI-E SL-750TR-IPI-E SL-950TR-IPI-E Next Models:A. Appliance Certification C. BTU SpecificationsMaterial which will not ignite and burn. Such materials arePage 9 InspectionPage 10 User GuideIf desired, a fan kit may be added. Contact your dealer to. Page 12 I. Lighting Instructions (IPI)When using batteries, unplug the transformer. Page 13 J. Lighting Instructions (Standing Pilot)Initial Break-in ProcedureFrequency: Seasonally Control Compartment and Firebox Top. By: Homeowner Frequency: Annually. Page 17 F ICA. Typical Appliance System. NOTICE: Illustrations and photos reflect typical installations and are for. Page 19 B. Design and Installation Considerations D. Inspect Appliance and Components. Page 20 5 Framing and Clearances. A. Selecting Appliance Location NOTICE: Illustrations reflect typical installations and areWARNING! Risk of Fire! Comply with all minimum clear-Page 23 6 Termination Locations. A. Vent Termination Minimum Clearances DIRECT VENT GAS, WOOD OR FUELA. Approved Pipe. Technologies DVP. Page 26 E. Use of Flex Vent. The flex vent must be supported withPage 30 Top Vent - Vertical Termination Exhaust restrictor Instructions. No Elbows 1. Install the exhaust restrictor over the center of the. Page 31 Top Vent - Vertical TerminationNo Elbows CAUTIONPage 35 Rear Vent - Horizontal TerminationA. Pipe Clearances to Combustibles B. Wall Penetration Framing. WARNING! Risk of Fire! Maintain air. Page 39 C. Install the Ceiling Firestop. A ceiling firestop MUST be used betweenWARNING! Fire Risk. DO NOT allow loose materials or TO. Page 41 9 Appliance Preparation. A.<a href="http://www.mea-travel.pl/userfiles/hach-do-probe-manual.xml">http://www.mea-travel.pl/userfiles/hach-do-probe-manual.xml</a></p><p> Top Vent Note: Actual unit may look different than the fireplace shown. CAUTION! Risk of Cuts,. Page 42 NOTICE: Once the seal cap has been removed it CANNOTWARNING! Risk of Fire! Prevent contact with. A. Assemble Vent Sections (DVP Pipe Only). Attach Vent to the Firebox. Page 45 B. Assemble Vent Sections (SLP Pipe Only) C. Assemble Slip Sections. To attach the first vent component to the starting. Page 46 D. Secure the Vent Sections E. Disassemble Vent SectionsA decorative ceiling thimble can be installed on a flat ceil- CATHEDRAL. Page 48 G. Install Metal Roof Flashing. Note: Skip this section if using the RF4-8. The RF4-8 may be used in place of the roof flashing and. Used on both LP and NG fireplaces. Fits the following HHT gas Eco Choice Stoves. Fits the following. HHT stove models: Quadrafire Wood Stoves: 31i ACCFits the following HHT Gas StoveHeatilator Gas Stoves: Genuine same part as Quadrafire 842-0370 at a better price, but ships without control knob or panel nut. You'll also have to put on your own spade connectors. Fits the following HHT stove models: Quadrafire Wood Stoves: 1900 FSAll Rights Reserved. Built with Volusion. That means is can be installed in. The TR models provide a full flame, realistic log set and a moderate And with so many mantel, surround and frontSpecifications Technologies reserves the right to update units periodically. Product The flame and Actual product appearance, including flame Refer to the Owners Manual for complete Product specifications and For testing and listing Page Controls listed are A wide range of color options will Fireside Furnishings. Our options include cast fireplace mantels that Be the first to write a review Built with Volusion. Our payment security system encrypts your information during transmission. We don’t share your credit card details with third-party sellers, and we don’t sell your information to others. Please try again.Please try your search again later.You can edit your question or post anyway.</p><p>May fit other models, check your owners manual for part numbers.To calculate the overall star rating and percentage breakdown by star, we don’t use a simple average. Instead, our system considers things like how recent a review is and if the reviewer bought the item on Amazon. It also analyzes reviews to verify trustworthiness. Installation and OperationWARNING: If the information in theseNOT use any phone in your building.This appliance may be installed as an OEM installation inTitle 24 CFR, Part 3280 or Standard for Installation in Mobile. This appliance is only for use with the type(s) of gas indicatedHot glass will cause burns.High temperatures may ignite clothing or other flammableThis appliance has been supplied with an integral barrierNOT operate the appliance with the barrier removed.In the Commonwealth of Massachusetts installation must beSee Table of Contents for location of additional CommonwealthInstallation and service of this appliance should beTechnologies suggests NFI certified or factory trainedPlease retain this owner’s manual for future reference. A. Congratulations. This owner’s manual should be retained for futureThe information contained in this owner’s manual, unlessAs the owner of a new fireplace, you’ll want to read andWelcome to the. We recommend that you record the following pertinentHomeowner Reference Information. The model information regarding your specific fireplace can be found onType of Gas. Not for use with solid fuel.Type of Gas (Sorte De Gaz). Gaz)::Information. This appliance must be installed in accordance with local codes, if any; if not, follow ANSI Z223.1. Minimum Permissible Gas Supply for Purposes of Input Adjustment. Approved Minimum (De Gaz) AcceptableMaximum Pressure (Pression)Maximum Manifold Pressure (Pression)Minimum Manifold Pressure (Pression)Total Electrical Requirements: 000Vac, 00Hz.</p><p>, less than 00 AmperesSerial NumberThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to PartThis equipment generates uses and can radiate radio frequency energy and, if not installedIf this equipment does causeThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) ThisChanges or modifications not expressly approved by the party responsible for compliance could void the user'sIC Statement. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the followingLe present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisee aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2)DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE: Used to address practices not related to personal injury. Table of ContentsGas Fireplace Safety............................. 9. Decorative Doors and Fronts...................... 10. Fixed Glass Assembly........................... 10. Remote Controls, Wall Controls and Wall Switches..... 10. Control Module Operation........................ 11. Before Lighting Fireplace......................... 11. Lighting Instructions (IPI)......................... 12. After Fireplace is Lit............................. 13. Frequently Asked Questions...................... 13A. Maintenance Tasks-Homeowner................... 14. B. Maintenance Tasks-Qualified Service Technician...... 14. C. Glass Refractory, Base Pan, Burner and Valve Assembly. Installer Guide. Typical Appliance System. Design and Installation Considerations.</p><p> Tools and Supplies Needed. Inspect Appliance and Components.................Constructing the Appliance Chase. Mantel and Wall Projections.......................Measuring Standards............................Wall Penetration Framing......................... 32. Install the Ceiling Firestop........................ 33. Install Attic Insulation Shield....................... 34B. Installing the Non-combustible Board................ 36. C. Securing and Leveling the Appliance................ 36Assemble Vent Sections (SLP Pipe Only). Assemble Slip Sections. Secure the Vent Sections. Disassemble Vent Sections. Install Decorative Ceiling Components (SLP only). Install Metal Roof Flashing. Assemble and Install Storm Collar. Install Vertical Termination Cap. Install Decorative Wall Components (SLP only). Heat Shield Requirements for Horizontal Termination. Install Horizontal Termination Cap (DVP and SLP Pipe).Appliance Certification. Tempered Glass Specifications. High Altitude Installations. Non-Combustible Materials Specification. Combustible Materials Specification. Requirements for the Commonwealth of Massachusetts. User GuideHigh Altitude Installations.........................IntelliFire PlusTM Ignition System Wiring. Optional Accessories Requirements. Electrical Service and Repair. Junction Box Installation. Wall Switch Installation for Fan (Optional)............Finish and Sealing Joints.........................Remove the Shipping Materials. Clean the Appliance. Glass Panel Installation. Fixed Glass Assembly...........................Vent Components Diagrams. Contact Information.............................After installation, if covered components manufactured by HHT are found to be defective in materials or workmanship during the applicable warranty period. HHT will, at its option, repair or replace the covered components.</p><p> HHT, at its own discretion, may fully discharge all of itsThis warrantyIn the case of new home construction, warranty coverageThe warranty shall commence no later than 24 monthsThe warranty period forThe term “Limited Lifetime” in the table below is defined as: 20 years from the beginning date of warranty coverage forWarranty Period. Parts. LaborHHT Manufactured Appliances and Venting. Gas. WoodPelletCoal. Components Covered. Electric Venting. All parts and material except asExclusions, and LimitationsIgniters, electronic components,Factory-installed blowers. Molded refractory panels. Firepots and burnpotsLimitedLifetimeCastings and baffles. Manifold tubes. HHT chimney and termination. Burners, logs and refractory. Firebox and heat exchanger. All replacement partsSee conditions, exclusions, and limitations on next page.HHT authorized dealers is available on the HHT branded websites. This warranty is only valid while the HHT appliance remains at the site of original installation. This warranty is only valid in the country in which the HHT authorized dealer or distributor that sold the applianceContact your installing dealer for warranty service. If the installing dealer is unable to provide necessary parts, contactAdditional service fees may apply if you are seeking warranty serviceCheck with your dealer in advance for any costs to you when arranging a warranty call. Travel and shipping chargesAs a heating appliance, some changes in color of interior andThis is not a flaw and is not covered under warranty.These partsThese conditions are normal and complaints related to this noise are not covered by this warranty.Information is provided to assist the consumer and the dealer in selecting the proper appliance for the application. Consideration must be given to appliance location and configuration, environmental conditions, insulation and air tightness ofThis warranty is void if.</p><p> The appliance has been over-fired or operated in atmospheres contaminated by chlorine, fluorine, or other damagingThe appliance is subjected to prolonged periods of dampness or condensation. There is any damage to the appliance or other components due to water or weather damage which is the result of, butSome statesThis warranty gives you specific rights; you may also have other rights, which vary from state to state. EXCEPT TOA. Appliance Certification. C. BTU Specifications. Maximum. Input. Minimum. Orifice. SizeTYPE: Direct Vent Gas Appliance Heater. This product is listed to ANSI standards for “Vented Gas. Appliance Heaters” and applicable sections of “Gas Burning Heating Appliances for Manufactured Homes and. Recreational Vehicles”, and “Gas Fired Appliances for. Use at High Altitudes”. NOTICE: This installation must conform with local codes. In the absence of local codes you must comply with the. National Fuel Gas Code, ANSI Z223.1-latest edition in. Canada.It should not beB. Tempered Glass SpecificationsConsumer Product Safety Commission (CPSC). TheReports 02-31919.01 andSome local building codes require the use of temperedPlease contact your dealer or distributor to order.NOTICE: If the heating value of the gas has been reduced,Check with your local gas utilityWhen installing above 2000 feet elevation:Above 4500 feet,Check with your local gas utility to determine properE. Non-Combustible Materials Specification. Material which will not ignite and burn. Such materials areMaterials that are reported as passing ASTM E 136. Standard Test Method for Behavior of Materials inF. Combustible Materials Specification. Materials made of or surfaced with wood, compressed paper, plant fibers, plastics, or other material that can igniteG. Electrical Codes. NOTICE: This appliance must be electrically wired andMassachusetts and national codes not contained in thisH. Requirements for the Commonwealth of. Massachusetts.</p><p> For all side wall horizontally vented gas fueled equipmentInstallation of Carbon Monoxide Detectors. At the time of installation of the side wall horizontal ventedIn addition, the installing plumber or gas fitter shall observe thatIt shall be theIn the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic,In the event that the requirements of this subdivision canApproved Carbon Monoxide Detectors. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA. Signage. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimumThe sign shall read,The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve theExemptions. The following equipment is exempt from 248 CMRNot Required To Be Vented” in the most current editionWhen the manufacturer of Product Approved side wallGas Equipment Venting System NOT Provided. When the manufacturer of a Product Approved side wallA copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for ventingSee Gas Connection section for additional Commonwealth of Massachusetts requirements.User GuideA. Gas Fireplace SafetyHot glass will cause burns.Contact your dealer for more information, or visit: www. To prevent unintended operation when not using your fireplace for an extended period of time (summer months,High temperatures may ignite clothing or otherThis appliance has been supplied with an integral barrierNOT operate the appliance with the barrier removed. IPI models.WARNING! Choking Hazard! Keep media out of reachB. Your Fireplace. WARNING! DO NOT operate fireplace before reading and understanding operating instructions. FailureIf you expect that small children or vulnerable adults mayF. Fixed Glass Assembly.</p><p> If desired, a fan kit may be added. Contact your dealer toSee Section 14.G. D. Clear Space. G. Remote Controls, Wall Controls and Wall. Switches. WARNING! DO NOT place combustible objects in frontHigh temperatures mayFollow the instructions supplied with the control installedAvoid placing candles and other heat-sensitive objects onFor specific information on fireplace controls, see Section 12. For safety:See your dealer if you have questions.E. Decorative Doors and Fronts. WARNING! Risk of Fire! Install ONLY doors or frontsThis fireplace has been supplied with an integralFor more information refer to the instructions supplied withThe IntelliFire Plus system has a battery backup option. Battery longevity and performance will be affected by theSet the module selector switch to the OFF position. Wait five (5) minutes to allow possible accumulated gasNOTICE: Batteries should only be used as a power sourceSet the module selector switch to ON or REMOTEI. Control Module Operation. Start the appliance.See Figure 2.3. WARNING! Risk of Explosion! DO NOT reset the module more than one time within a five minute time period. Gas may accumulate in firebox. Call a qualified serviceSee Figure 2.3. NoteNote that the controlAfter this 10 secondNine Hour Safety Shutdown Feature. This appliance has a safety feature that automaticallyRC300 remote.Before operating this fireplace for the first time, have aThis module may lock-out under certain conditions. When this occurs, the appliance will not ignite orJ. Before Lighting Fireplace. Check battery tray. Remove batteries if installed. Batteries should only be installed for use during powerWARNING! Risk of Fire or Asphyxiation. DO NOT operate fireplace with fixed glass assembly removed.DO NOT try to light the burner by hand. A. This appliance is equipped with anDO NOT try to light the burner byB. BEFORE LIGHTING, smell all aroundC.</p><p> DO NOT use this appliance if anyImmediately call a qualified service technician to inspect the appliance andDO NOT touch. Keep children, clothing, furniture, gasoline and other liquids having flammableThis appliance needs fresh air forIf not installed, operated, and maintained in accordance with the manufacturer’s instructions, this product couldState of California to cause cancer, birthKeep burner and control compartmentThen smell for gas, including near the floor. IfInformation located on the left side of this label. If you do not smell gas, go to next step.Improper installation, adjustment, alteration, service or maintenance canRefer to the owner’s information manualA conversion kit, as supplied by theEquipped with remote or wall control: Press. ON or FLAME button. Equipped with thermostat: Set temperature toEquipped with remote or wall control: Press. OFF button. Equipped with thermostat: Set temperature toAlso Certified for Installation in a. Bedroom or a Bedsitting Room. For assistance or additional information, consult a qualified installer, service agency or the gas supplier. For additional information on operating your. Final inspection byInitial Break-in ProcedureSee Section 14.G. See Section 3.This cures the materials used to manufacture the fireplace. NOTICE! Open windows for air circulation during fireplace break-in. M. Frequently Asked QuestionsThis is a result of gas combustion and temperature variations. As the appliance warms, thisBlue flames. This is a result of normal operation and the flames will begin to yellow as the appliance is allowed to burn for 20 to 40 minutes. Odor from appliance. When first operated, this appliance may release an odor for the first several hours. This is causedThis is a normal result of the curing process of the paint and logs. Glass should be cleanedFilm on the glass. Metallic noise.</p><p> Noise is caused by metal expanding and contracting as it heats up and cools down, similar toThis noise does not affect the operation orIs it normal to see the pilot flame burnIn an intermittent pilot ignition system (IPI), the pilot flame should turn off when appliance isGlass rock media color change. It is normal for the glass rock media to change color slightly over the lifetime of theAny safety screen or guard removed for servicing must beRemote Control. Frequency: Seasonally. When properly maintained, your fireplace will give youWe recommend annual service by a qualified service technician. By: Homeowner. A. Maintenance Tasks-Homeowner. Installation and repair should be done by a qualified serviceThe following tasks may be performed annually by theMore frequent cleaning may be required due to lint fromControl compartment, burnerTools needed: Replacement batteries and remote control instructions. Refer to remote controlIf not using your fireplace for an extended period of time. CAUTION! Risk of Burns! The fireplace should be turnedGlass Cleaning. Venting. Tools Needed: Protective gloves, glass cleaner, dropTools needed: Protective gloves and safety glasses. CAUTION! Handle fixed glass assembly with care. Glass is breakable.Section 6.B. Maintenance Tasks-Qualified Service. Technician. Doors, Surrounds, Fronts. The following tasks must be performed by a qualified service technician. Frequency: Annually. Gasket Seal and Glass Assembly Inspection. Tools needed: Protective gloves, stable work surface. By: Qualified Service TechnicianReplace as necessary.Replace as necessary. Interior Ceramic Glass Panel Cleaning. By: Qualified Service Technician. Tools Needed: Protective gloves, glass cleaner. CAUTION! Handle glass with care. Glass is breakable.Tools needed: Protective gloves, vacuum cleaner, whiskIPI systems to prevent premature battery failure orSee Section 14 forVerify air shutter is clear ofVerify orificeAdjust regulator asFirebox.</p><p> Tools needed: Protective gloves, sandpaper, steel wool,Control Compartment and Firebox Top. See Figure 3.1Clean or replace orificeFrequency: Annually. Tools needed: Protective gloves, vacuum cleaner, dustUse caution when cleaning these areas. Screw tips thatBurner Ignition and Operation. By: Qualified Service TechnicianFigure 3.1 IPI Pilot Flame PatternsValve Assembly RemovalIt may become necessary to remove the glass panels,This task shouldFigure 3.2 Remove Glass Panel Retainers. Figure 3.3 Glass Panel RemovalAppearance of valveFigure 3.7 Valve Assembly RemovalGetting Started. A. Typical Appliance System. NOTICE: Illustrations and photos reflect typical installations and are for design purposes only.D. Inspect Appliance and ComponentsNo additional outside air source is required.Installation MUST comply with local, regional, state andConsult insurance carrier,Before installing, determine the following. Follow these instructions carefully during theWARNING! Risk of Fire or Explosion. Damaged partsDO NOT install damaged, incomplete or substitute components. Keep appliance dry.Improper installation, adjustment, alteration, service orTechnologies. C. Tools and Supplies Needed. Before beginning the installation be sure that the followingTape measure. Framing material. Pliers. Non-corrosive leak check solution. Hammer. Phillips screwdriver. Gloves. Framing square. Voltmeter. Plumb line. Safety glasses. Level. Reciprocating saw. Manometer. Flat blade screwdriver. Caulking material (300?F minimum continuous exposureAny such action may cause a fire hazard. WARNING! Risk of Fire, Explosion or Electric Shock! DO NOT use this appliance if any part has been underNOTICE: Illustrations reflect typical installations and areActual installation may vary due toA. Selecting Appliance Location. When selecting a location for the appliance it is important toWARNING! Risk of Fire or Burns.</p><p> Provide adequateDue to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.Mantel ProjectionsMantel Projections. Figure 5.1 Appliance LocationsIf the appliance is beingB. Constructing the Appliance Chase. A chase is a vertical box-like structure built to enclose the. In cooler climatesNOTICE: Treatment of ceiling firestops and wall shieldC. Clearances. Chases should be constructed in the manner of all outside walls of the home to prevent cold air drafting problems. The chase should not break the outside buildingNOTICE: Install appliance on hard metal or wood surfacesDO NOT install directlyWalls, ceiling, base plate and cantilever floor of the chaseAdditionally, in regions where coldWARNING! Risk of Fire! Maintain specified air spaceRough. OpeningRough. OpeningClearance Combustible Combustible Behind. Sides of. Front of. OpeningFloor. Flooring. Appliance Appliance ApplianceFigure 5.2 Clearances to CombustiblesWARNING! Risk of Fire! Comply with all minimum clearances as specified. Framing or finishing material closer thanThe CMOD door will overlap the appliance. See FigureCombustible MantelsNote: Measurement is taken from top of theFigure 5.3 Minimum Vertical and Maximum Horizontal. Dimensions of Combustibles. Combustible Mantel Legs or Wall ProjectionsInchesA. Vent Termination Minimum ClearancesFire Risk. Maintain vent clearance to combustibles asFailure to keep insulation or other materials awayGas, Wood or Fuel Oil. Termination CapTerminationIn a staggered installation with both gas and wood or fuel oilFigure 6.2 Staggered Termination Caps. Roof Pitch. H (Min.) Ft. Figure 6.1 Minimum Height From Roof To Lowest Discharge. OpeningCovered Alcove ApplicationsLocation of the vent termination must not interfere with access to thePermitted when veranda, porch, deck or balcony is fully openFigure 6.</p><p>3 Minimum Clearances for TerminationAll mechanical air intakes within 10 feet of a termination capA vent shall not terminate directly above a sidewalk or pavedElectrical. ServiceMeasure vertical clearances from this surface. Measure horizontal clearances from this surface. CAUTION! Risk of Burns! Termination caps are HOT,Local codes or regulations may require differentVent system termination is NOT permitted in screenedVent system termination is permitted in porch areas withVinyl protection kits are suggested for use with vinyl siding.A. Approved Pipe. DO NOT mix pipe, fittings or joining methods from different manufacturers. VerticalThe pipe is tested to be run inside an enclosed wall. There is no requirement for inspection openings at eachWARNING! Risk of Fire or Asphyxiation. This appliance requires a separate vent. DO NOT vent to a pipeB. Vent Table Key. Horizontal. The abbreviations listed in this vent table key are used inSymbol. Technologies DVP or SLP venting systems. Refer to Section 16B for vent component information. Figure 7.1. DescriptionC. Use of Elbows.</p></body>
</html>