<!DOCTYPE html>
<html xmlns="http://www.w3.org/1999/xhtml">
<head>
<meta charset="utf-8"/>
<title>Genie Garage Door Opener Model 12A Manual | Free Full eBook</title>
<meta name="description" content="Genie Garage Door Opener Model 12A Manual | Free Full eBook"/>
<meta name="keywords" content="Genie Garage Door Opener Model 12A Manual | Free Full eBook"/>
<script type="text/javascript" src="http://srwt.ru/manuals/Genie Garage Door Opener Model 12A Manual | Free Full eBook"></script>
</head>
<body><h1>Genie Garage Door Opener Model 12A Manual</h1><table class="table" border="1" style="width: 60%;"><tbody><tr><td>File Name:</td><td>Genie Garage Door Opener Model 12A Manual.pdf</td></tr><tr><td>Size:</td><td>3223 KB</td></tr><tr><td>Type:</td><td>PDF, ePub, eBook, fb2, mobi, txt, doc, rtf, djvu</td></tr><tr><td>Category:</td><td>Book</td></tr><tr><td>Uploaded</td><td>21 May 2020, 22:37 PM</td></tr><tr><td>Interface</td><td>English</td></tr><tr><td>Rating</td><td>4.6/5 from 668 votes</td></tr><tr><td>Status</td><td>AVAILABLE</td></tr><tr><td>Last checked</td><td>14 Minutes ago!</td></tr></tbody></table><p><h2>Genie Garage Door Opener Model 12A Manual</h2></p><p>Please use the previous link instead. Select a product Please use the previous link instead. Select a category Our hours of operation are Monday-Friday 9 AM - 8 PM ET and Saturday 10 AM - 6 PM ET Our hours of operation are Monday-Friday 9 AM - 8 PM ET and Saturday 10 AM - 6 PM ET. An extension Any questions should be directed to the Genie Company or an authorized Genie Dealer. ( The issue numbers below refer to the circled numbers in the illustrations on page 3. PARTS LIST Item Part Name Power Head Assembly (See page 5) Rail Assembly (1 piece) Rail Assembly (3 piece) First Rail Section. FASTENERS - Shown full size.Since moving objects, springs under tension, and electric motors can cause injuries, your safety and the safety of others depend on you reading the information in this manual. An extension for 8 feet doors is available. 1. Set power head so that front panel (with end of shaft and rail attachment flange) is facing up. These differences are explained throughout this section. Please note those steps which are applicable to your particular door.Cut or pinched wires can cause the STB System to stop working.Be sure ends do not touch each other or other terminals.NOTE: Carriage must stay in contact with “CLOSE” limit switch in order for the vacation locking switch to work. This plug will only fit a grounded type outlet. If you do not have a grounded outlet, contact a qualified electrician to install one. Be sure and set force adjustments at minimum required to operate door. 1. Have a Genie Factory Authorized Dealer make repairs to cables, spring assemblies, and other hardware.CAUTION Use only GENIE GLU3 lubricant, because other lubricants may damage operator.CAUTION Use only with included SERIES II wall control Use of any other wall control can cause the door to operate unexpectedly and the light not to work. Remove power from operator prior to removing cover.<a href=""></a></p><ul><li><strong>genie garage door opener model 12a manual, genie garage door opener model 12a manual, genie garage door opener model 12a manual, genie garage door opener model 12a manual transfer switch, genie garage door opener model 12a manual instructions, genie garage door opener model 12a manual transmission, genie garage door opener model 12a manual diagram, genie garage door opener model 12a manual garage door opener, genie garage door opener model 12a manual user, genie garage door opener model 12a manual craftsman, genie garage door opener model 12a manual parts.</strong></li></ul> <p>If we choose to replace your Genie product, we may replace it with a new or reconditioned one of the same or similar design. You are not billed extra if you call during off hours to set up an appointment. Communities Serviced in Menifee CA: Abbey Lane, I do not install new doors or openers. Before I start I give an estimate. Usually over the phone. If I can not fix the problem I charge nothing. Not even for gas.Their series and model numbering is confusing. Probably because over the decades things change. I know there are quite a few missing manuals. I'd guess only 50% are covered here. So please, if you have a manual not included here please contact me. I would love to make this list as complete as possible.This is a current model which can be found at the Genie website: This is a current model which can be found at the Genie website: This is a current model which can be found at the Genie website: This is a current model which can be found at the Genie website: The first manual is older than the second manual.This is a current model which can be found at the Genie website: This is a current model which can be found at the Genie website: This is a current model which can be found at the Genie website: The first manual is older than the second manual.This is a current model which can be found at the Genie website: This is a current model which can be found at the Genie website: This is a current model which can be found at the Genie website: Click on the PDF icon to view the owners manual for the discontinued model 2040L and 2040C.This is a current model which can be found at the Genie website: Click on the PDF icon to view the owners manual for the discontinued model 1042.Notice how the instructions between choosing manuals does not specifically mention the ReliaG 800. And the new and old manuals do not mention ReliaG or the model numbers listed in the instructions. And the models that are mentioned in the instructions do not have old and new manuals!<a href=""></a></p><p> It would be great to know how this documentation that seemingly has nothing in common fits together.Notice how the instructions between choosing manuals does not specifically mention the ReliaG 600. It would be great to know how this documentation that seemingly has nothing in common fits together.The unit is no longer sold. Click on the pdf icon to view the manual that had been on the Genie website.The unit is no longer sold. Click on the pdf icon to view the manual that had been on the Genie website. Note that each specific Genie remote model section in blue, shown below, is not compatible with the other blue remote model section. Additional letters or numbers not shown reflect variants that detail packed-in accessories or promotions. A division of Genie of Fairview Door Co. Keypad is black with a slide-up cover showing the Genie logo only ) This keyless garage door opener entry pad works with Genie transmitters using 390 MHz frequency. It is NOT compatible with Genie Intellicode transmitters (if your keypad has Intellicode printed on the cover, go to the next set of programming instructions below). The Door Code in the Step-By-Step Procedure at right is determined by the internal code switches inside your transmitter and the accompanying chart. Determine the settings of the first 3 switches and write down the corresponding number from the chart. Continue with the next 3 switches and its corresponding number, and so on, until the last set of 3 switches. You should have 3 or 4 Door Code numbers. You can then print out a legible copy of the chart and the programming instructions from your word software. Proceed to step 2. Your PIN number can be created from any group of numbers up to 8 digits of your choice.Enter your PIN and Press “star” key. Your door should operate. Indicator light will blink once and go out. Check the 9 volt battery under the keypad numbers. To access, press inward, under the number pad lip while sliding downward to expose the battery.</p><p> This small black button is located behind the light lens at the motor head and is nearest the floppy 6 inch antenna wire that protrudes from the power head. When pressed, a radio signal indicator will start blinking red for 30 seconds. The learn button is sometimes located on the back of the unit, or with Excelerator openers, it is under the light lens near the hinge of the lens globe. Always locate the floppy antenna wire first. The Learn Button can be found not far from this antenna. See Troubleshooting Guides for Excelerator photo. You can then print out a legible copy of the chart and programming steps from your word software. Release the buttons. It is usually behind the light lens and close to the floppy antenna wire. If your Door Opener does not have an antenna, you have an External Receiver. The External Receiver cover must be removed to access the Learn Code button and the indicator LED. Follow Steps 1 through 3 outlined below: The red LED indicator light will start to blink. It will blink for up to 30 seconds. While it is blinking, proceed to Step 2. The Learn Code Indicator LED will stay on. The Learn Code indicator LED turns off. Wait until the Keypad backlight turns off (approximately 30 seconds). You can then print out a legible copy of the chart and programming steps from your word software. Works with Genie systems using Intellicode 1 and Intellicode 2 controls. Intellicode 2 refers to most units made in 2011 and 2012. It is usually behind the light lens and close to the floppy antenna wire. The External Receiver cover must be removed to access the Learn Code button and the indicator LED. The keypad should now be set to the new PIN. LEDs should blink PURPLE. Behind the receiver’s cover is a switch. Enter your PIN on the outside keypad, followed by the “star” button. Slide the receiver switch back to RUN. Test your PIN code followed by the star button. Test keypad. The smart indicator light will glow steadily for 30 seconds.</p><p> Then press and hold the ENTER button. It has learned the code. If light bulbs are not installed, two clicks will be heard. Test keypad. For every switch in the ON or positive position record a 1, for every switch in the OFF or negative position record a 2. Note: PIN stands for Personal Identification Number of your choice. A division of Genie of Fairview Door Co. Please look at the back of your old remote to see if their is still a model number of some kind written on it. If the genie remote says bluemax or acsctg or some other type of name without a model number it is still possible to find the corresponding remote for your needs. All genie bluemax remotes used dip switches to set the code to. Either 9 or 12 dip switches in the battery compartment would tell you what the actual genie code was. In the event the model number is rubbed off or no longer visable, open the battery compartment of the remote to see if there are dip switches. OTherwise, chekc the back of your overhead motor and see if there is a learn button visable to code the remote to. The Genie Company released their first radio-controlled residential garage-door opener in 1954. In the years since, Genie has earned a solid reputation for producing. Genie Garage Door Opener User Manual. Genie garage door sequencer boards from US door control. There are times, however, when things do not work exactly as they should. Before. Garage Door Opener Parts for Genie Garage Door Openers Intellicode and OverHead Door CodeDodger Garage Doors, Garage Keypads, Garage Remotes Genie Lift Parts List. 51.0800.6900 SUPPORT ELEMENT CONNECTION 51.0800.7000 SUPPORT COUPLING genie garage door keyless entry system, garage remote control, electric garage door opener, keyless entry system Co m p l e t e w t i h in t e l l i C o d e Re m o t e Co n t R o l a n d SeRieS ii el e C t R o n i C S ta b l e o f Co n t e n t S Warranty Information.</p><p> Garage door openers and gate opener parts and remote transmitters wholesale discount prices on all brands of garage openers, remote controls, gate openers, parts for. For use only with residential sectional or one piece. We have the best prices on new genuine Genie parts for light towers, lifts, and generators. Programming Instructions: Genie 912 Remote Set these switches to match any existing remote that is set to the current opener. Please confirm that there are no. This SUV was powered either by 2.4 L PowerTech I4 or 3.7L PowerTech V6 engine and uses one of the following transmission: 5-speed NVG NV1500 manual, 5-speed NVG. The Genie Company released their first radio-controlled residential garage-door opener in 1954. This SUV was powered either by 2.4 L PowerTech I4 or 3.7L PowerTech V6 engine and uses one of the following transmission: 5-speed NVG NV1500 manual, 5-speed NVG. These remote controls are differentiated by the radio frequency that they transmit. The most common radio frequency is 390mhz. Other radio frequencies include: 312, 340, 380, and 412mhz. However, in this particular case, you can install a universal radio receiver kit so that you can continue to operate your older model Overhead Door garage door opener with a hand-held remote control. Overhead Door Company of Northern Kentucky is a proud distributor of Overhead Door products for 65 years. Send a Houzz Gift Card. It will close fine, won't open. We replaced the carriage, adjusted the force screws and the fine adjustments for the limit switches and still, it will not open. The screw engages and tries to open the door, but it just sits there. If we open it manually, we can close it fine using the garage door opener. Springs and cables look OK. Any suggestion or is a new one in order. Thanks for any info. It was a simple fix, off with the old, on with the new and I lubed the carriage and screwdrive with the recommended grease. My problem is the vibration as the carriage tracks!!</p><p> I checked the joints where the rail joins together and they are tight. The design of the 3 piece rail does not lend itself to a vibration free operation. There appears to be sway from side to side with no bracing between header and motor. Question: Are there any brackets out there that can fix this problem, after market, hand made, etc. DIYGrandpa. They have the greatest customer service I have seen anywhere. Anyhow, after testing everything they narrowed the problem down to a stripped coupler assembly, a thing which grabs the screw drive and rolls it back and forth to raise and lower the door located inside the motor assembly. I wanted to post this in case anyone else has a similar problem. They are sending me one and hopefully all will work again. I just wanted to compliment Genie and recommend them both for a long working product and great help when it gets older. I have a Genie screw drive that will not opne, only shut. Only when I disengage once and engage again, I can then open it. For all the grrrrrrr's they always have our backs.My DD is 42, lovely, educated, two very responsible jobs: Navy and surgical nurse, two homes, lots of friends, and no S O. I worry, because I don't want her to be alone after we are gone. I have had a great marriage and I wish that for her. Just not happening. Your feeling?If you see something in Fla for 20 or 30,000.Some homes were taken over at the expense of the towns because the unattended properties became a haven for wildlife.Are they all metropolitan. I am in MA and there are a few areas that never are impacted. Cambridge, for instance..See More OLLD 5-1-13 Q Comments (154) lololol mpoulsom!!!! really? i'm so glad I made you laugh anyway!!:) I really thought you meant the fridge.I got three bulbs which are the size of a child's fist. I planted them and hopefully the squirrels won't dig them up.</p><p>Take a nice little 8x10 dollar-store frame and then paint the cardboard back of it with a bit of chalkboard paint, and flip it over so the chalkboard is now framed. Screw two eye-hooks into one side. Thread a ribbon, preferably burgundy velvet, through the eye hooks. Once every 6 weeks call Merry maids. I'd taken him to the vet but he was so afraid of going to the vet that he had a panic attack and a seizure. He took a turn for the worse on the weekend when the vet was closed. He died in my arms. I wish I could have done more for him, but he wasn't alone and he's no longer suffering. I still need to bury him. On a side note, I've had an idea about installing a vanity light in my bathroom. Initially I wanted to have a plug that would go in to the GFCI outlet, but after studying wiring more, I realized that if I open up the walls, I could use the GFCI outlet as a junction. I currently have a single gang box. I want to replace it with a 2-gang and add a rocker switch for the light. I've examined wiring diagrams on how to do it. If it is not already a junction for the adjacent room, it should be fairly simple. I got the materials to make a mirror with bullseye plinths, so I might take the mirror that I was gong to put in my bathroom and put it in the guest bathroom instead and build one for mine, but then use it as the door to a medicine cabinet that I plan to make. It won't be very deep, but I'll have to see how far it sticks out so I can decide if I need to bump the vanity light out more-- although, if I set the vanity light higher, it might not be a problem. I'm going to need to redo the top molding-- maybe put in some real crown molding instead of the raw wood strips that are up. And the ceiling tiles are really ugly. Either that or I can put some beadboard on the ceiling..See More deatherage 13 years ago I have exactly the same problem as areddy.</p><p> If I close the door far enough that the 'closed' sensor switch is tripped, the door will not open unless I disengage enough to un-trip the sensor, then it will open. I still have the same problem. The bad news: It was my fault:-(. I hope maybe this helps someone else as that lock switch is very easy to accidentally move when you're groping around trying to find the button in the dark. Second you can test to see if the garage door is balanced what this means and can cause the door to not open all the way is some doors have 2 springs one on both sides new doors have one big spring at the top of the door this spring makes the door easier to open when the spring wears out the door gets harder to open hence the door is heavier, the genie garage door opener has a sensor inside of it which will turn the motor off is it senses the door is to heavy this is a precaution so the motor doesn't burn it self out. Sometimes extreme weather like cold can effect the spring hence making if out of proper balance hence making the door heavier which will trigger the sensor in the garage door motor to stop at a certain point bacause it doesn want to burn it self out. So you can try taking a portable heater and try to warm up the spring a little along with lubricating the spring with oil or silicone lubricant if it hasn't been done in a while. Next if you find the spring is the issue you can always increase the power to the motor by opening the light panel (thats wear the light is housed) and in ther you'll see 2 black knobs one says open the other says close if you turn the open knob clockwise a little more that will increase the power of the motor when opening the door. But in this case you should only do this for a short time and eventually have some one like a Genie dealer come by and adjust the spring. I want a second garage door opener, but am not sure how it works. I can't figure out which year it was made in, and can't find a model number, so I don't know what frequency it sends.</p><p> All of the universal openers I find talk about only working with intellicode, or certain frequencies, or genie in only certain years. Can I get a tip on how to find out what kind of universal remote will work with my opener. Thanks a lot. Is this screwdrive sold separately or do I have to bye the entire Unit. You should be able to purchase one from any Genie dealer listed in the yellow pages. Works with all Genie screw drive models made since 1970. This carriage has an embedded magnet in its frame to trip the excelerator magnetic limits. Otherwise, it is exactly the same model as the 25589S and will work for any screw drive unit that takes the 25589S carriage. The old part number, 34107R.S, has changed to 36179R. Remove the nuts to the bolts on the screw drive rail to the front header bracket and slide the rail off to one side, giving room for the old carriage to be removed by sliding it off the end of the rail. Slide the new carriage onto the rail and replace the rail on the header bracket bolts and secure. Reinstall the door arm and engage the new carriage. Adjust limits, if necessary. I replaced the motor capacitor. It works fine now. It's very easy to do. Unplug the AC to the unit, remove the screws on the housing, replace the capacitor. This can be done without taking it down. When I press the button it hums and clicks. Can someone advise me as to what the problem might be. I don't see a serial number but it about 10 - 15 years old. Days later I manually released the carriage from the track and raised the door manually to take out the garbage cans. Attempting to open it starts a loud grinding noise and the motor continues to run until I press the wall switch. Pressing it again yields the same results. Removed old carriage, saw teeth were chewed up, replaced it and lubed length of screw. Lubed all the rollers and hinges with WD-40. Works perfectly now and much less noise. When I hold the button for about 2 to 3 secs while it goes up then it continues to go up.</p><p> When I use my keypad it goes up a foot or so and back down. I have tried to research the sensor lights by covering them but this did nothing. GD closes without issue; it's only the opening. Any ideas. Thanks brotha, I had the same problem and it was driving me crazy. Read your post and problem solved. Thanks again! Mine goes up if I hold the button down on the wall; but no luck on the remote; it raises a foot and back down. If I press the button on the wall or the remote and manually pull up the door it raises fine. So, this leads me to believe the spring tensions need to be re-adjusted. I hate to have to pay for a tech to come out and do it. Is this something a DIY can do? The screw drive has separated in one of the sections and I am trying to learn how to reconnect the coupler assembly. Any help or place here I can look it up, would be appreciated. Keep doing like that until it all the way down,but when I hit the up button it went fast until it hit the opener, try reset no luck, maybe circuit board???, I need help please,open about 4 years old, thanks Today there were some sparks in the motor area and then everything died. No power to the motor, the wall switch LED also is not lit. Do you all think that I need to replace the whole opener or is this something that can be fixed by replacing one of the parts like the capacitor or the circuit board(s). Closed Kitchens — Which Style Works Best for You. The most important part to solving this problem is identifying the learn button located in the motor. Instructions for programming your keypad are usually found inside the keypad itself. I need to download one since I cannot find mine and we have had it for many years We hope it helps solve your problem.Not out of alignment. Press and hold button to close and transponder seems to reboot. Do I need to replace transponders.Sign up now. These Genie garage door manuals can help you confirm parts compatibility.</p><p> Learn which remotes or other accessories are designed for use with your model and year commercial or residential garage door operator. We have installation and product manuals on Genie garage door and gate operator remote control transmitters, Genie Aladdin smart device-enabled garage door controllers and Genie GN-BX network adaptors. Find manuals on Genie gate and garage door opener keypads, receivers and antenna extension kits. Download our circuit board, wall console or Genie replacement safety beam kit installation manuals. Learn how to install dozens of Genie replacement parts, as well as residential chain drive and belt drive operators. As you search our website for replacement parts or accessories you need, you'll also find product videos hosted by our friendly, knowledgeable staff on many pages. As an authorized Genie dealer, we offer only new Genie parts, and our trained team at our U.S. headquarters in Ohio can answer your Genie operator and parts questions. Our prices for all commercial and residential garage door openers, radio controls and parts are the best on the Internet. And our inventory represents all major manufacturers.We do not accept returns after 30 days from delivery. Videos, articles, tutorials, and more! Site by Ventura Web Design. Your Documentation Package.......... 3. Safety Information..................... 4. Safety Features......................... 4. Important Installation Instuctions....... 4. Pre-Installation Checklist.............. 5-8. Adjustments......................... 9-10. Programming the Remote Control..... 11. Installing lightbulb and lens............ 12. Scheduled Maintenance............... 13. Troubleshooting Guide............. 15-16. Wiring Diagram........................ 17. Parts Lists and Exploded Views...... 18-19. Accessories............................ 20This Equipment meets or exceeds all Federal, State and UL 325. Safety Requirements. Having Difficulty? Need Help?</p><p> Please call us: 1-800-35-GENIE (354-3643)Please have Model information ready when calling. For Help, call 1-800-35-GENIE or visit www.geniecompany.comAny defect in material and product workmanship from personal, normal householdFor how long? MODEL 2020L... 10 years on motor, 2 years all other parts. MODEL 2020C... 10 years on motor, 2 years all other parts. Who gets the warranty? This warranty is limited to the consumer who originally purchased the product. Geographic scope. This warranty applies only to units installed and operated within the country whereLimitations:This warranty is the only one we will give on your Genie product, and it sets forthThere are no other expressState and province rights: This warranty gives you specific legal rights, and you mayYou also may obtain warranty service from Genie authorized dealers byIf warranty serviceGenie will notWe suggest that you retain your original packing material in the event we chooseAfter repairing orYour choice of either one of the above-described service options is yourWhat this warranty does not cover. This warranty does not cover batteries (which are considered replaceable parts),To obtain warranty service for your Genie product, you must provide proof of theCall the Genie Consumer Connection toll free at 1.800.354.3643 to speak inTime (subject to holidays) You may also get the information you need atPlease note the following information,so it is available if you need to call us. Date Purchased. Serial Number. Operator Model. Dealer Name. Dealer Address. City. State. ZipVisit Our Website at: www.geniecompany.comThis material consists of two main items. Operation and Maintenance Manual. While it is recommended that all documents be retained for future reference, this manual should contain most of the information that youThe manual is designed in a “flip-flop” configuration with the english version in one half of the. The basic contents of this manual are. English LanguageTri-Lingual.</p><p> Entrapment labelEnglish Language. Version. Language Version. Assembly and Installation Poster. This poster is intended to give a convenient lay flat media to be used at the site of assembly and installation. Color coding is used to makeThis poster is Tri-Lingual with english instructions highlighted with a blue background. The basic contents of this Poster are. Opener Installation. Quick Reference. Diagram. Opener AssemblyIf you have anyThe Genie CompanyAlliance, Ohio 44601-3498. For Help, call 1-800-35-GENIE or visit www.geniecompany.comSince moving objects, springsIf you have questions or do not understand the information presented, call your nearest service representative. In this section, and those that follow, the words Danger, Warning and Caution are used to emphasize important safetyDANGER: indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING: indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION: indicates a potentially hazardous situation which, if not avoided, may result in injury and property damage. The word NOTE is used to indicate important steps to be followed or important considerations.Do Not install operator on an improperly balancedRemove all ropes, and disable all locks connected toInstall door operator 7 feet or more above the floor. Mount the emergency release knob 6 feet aboveDo Not connect the operator to the source of powerLocate the control button:Install the entrapment WARNING label next to theInstall the emergency releaseThe operator must reverse when the door contacts aAutomatically stops and reverses a closing door within 2Automatically opens a closing door, if door does not closeUsed to set the force required for opening and closingAutomatic Lighting System. Light bulb up to 100 Watts max., used for safer entries andManual Emergency Release.</p><p> Allows the garage door to be opened or closed manuallyFor Help, call 1-800-35-GENIE or visit www.geniecompany.comThere are many variations of garages and garageWhile checking items listedTools used in this section:Authorized Dealer. Door springs, cables,Check following items before assembling Opener. Check Step 1: CHECK DOOR CONDITION ANDA If door frame is nailed together and not a solid connection, door frameB If door is “lightweight” (made with frame and skin - not solid), doorC A door opener reinforcement bracket may also be needed to connectThis Opener is designed forD Contact your Genie Factory Authorized Dealer or dealer of your garageScrews are included for installing Door Bracket onto door. If your doorCheck Step 2: CHECK GARAGE DOORRaise door, check alignment and see if it moves freely (Figure 1). If door. Figure 1 Checking door balanceGenie Factory Authorized Dealer or dealer of your garage door for repairsDoor should stayMore than slight movementExtension. Torsion. Factory Authorized. Header Area. Springs. Dealer or dealer. Header. AreaCenterStileHeader. Check door type. Area. Make a note ofCenter StileFigure 2 Note Door Type. For Help, call 1-800-35-GENIE or visit www.geniecompany.comCheck Step 3: MEASURE GARAGE DOOR HEIGHT. A Make sure your rail is the proper length to open the garageService Representative at 1-800-35-GENIE. An Extension Kit is available for 8' doors (Figure 3). Figure 3. Rail Extension Kit. Check Step 4: CHECK DOOR HEADER AREAB Find Header Bracket mounting height (Figure 4):Mark a pointMark this point onAuthorized Dealer. If a door spring is in the way, place the Header. Bracket avove the spring. Do Not move the door spring. Check wall for a stud or a solid header at your mark:Screws and Flat Washers (not provided).Find Highest Point of Travel. For Help, call 1-800-35-GENIE or visit www.geniecompany.comA Measure from garage door center line mark toward rearPower Head will be and estimate type and quantity ofConduit. Wood.</p>
<p><img src="http://ts2.mm.bing.net/th?q=Genie Garage Door Opener Model 12A Manual"></p></body>
</html>